VALUE AND APPLICABILITY OF TIDAL BREATHING FLOW VOLUME CURVE IN
ASSESSMENT OF AIRFLOW OBSTRUCTION IN BABIES WITH BRONCHIOLITIS
Cui ZZ, Li XH, Fang F, Ma XH, Cao CJ
Dalian Children's
Hospital, Dalian, China
Objective: To evaluate the value and applicability
of tidal breathing flow volume curve (TBFV) expressed as TV/Kg, %V-PF,
25/PF, PF/Ve, ME/MI, Crs, Rrs in assessing airflow obstruction in babies
with bronchiolitis, and those parameters�� relativity with PCO2
or PO2 .
Methods��The
authors measured TBFV in 31 babies with bronchiolitis and 30 healthy babies,
while measured blood analysis in babies with bronchiolitis with distal
blood which was arterialized.
Results��In
babies with bronchiolitis, the mean TV/Kg, %V-PF, 25/PF, PF/Ve, ME/MI, Crs,
Rrs separately were 6.49��1.52 ml,
0.14��0.08, 0.37��0.16, 2.15��0.58 0.50��0.07, 1.32��0.16,
0.007 �� 0.002,
which were significantly change as compared with healthy subjects��8.43��1.31ml,
0.29��0.14, 0.69��0.10, 1.49��0.40, 0.93��0.04, 1.32��0.45, 0.04��0.01, P<0.01) except Crs, Rrs. There was a positive correlation between PCO2 and Rrs��r = 0.45, P<0.05)��or between PO2 and TV/Kg or Crs��r =0.39 ,P<0.05��0.52, P<0.01).
Conclusions��TBFV��s
parameters TV/Kg, %V-PF, 25/PF, PF/Ve, ME/MI could reflect the airflow
obstruction in babies with bronchiolitis, and there was a lower positive correlation between PCO2
and Rrs or PO2 and TV/Kg, a significant correlation between PO2 and Crs.